Temperature Data Logger PCE-MPC 15

Product Code:
PCE-MPC 15
Availability:
In Stock
Delivery Time
2–3 Business Days

Need Technical Support?

Our engineers are available to help you select the right module for your application.

Description

Description

Temperature data logger for indicative measurement / Adjustable alarm limits / Data logger /
Micro USB charging interface / Measuring range 0 ... 1000 µg/m³ / Mass concentration /
Approx. 9 hours of battery life / 3.2" color display / Carrying case / 1/4" tripod connection

The temperature data logger is used in offices, workshops or in laboratories to carry out indicative measurements of the environmental conditions. In addition to the number of particles, the particle counter determines the mass concentration of PM2.5 and PM10 in the measuring range 0 … 1000 µg/m³. In addition, the temperature and the ambient humidity are measured. With the alarm limit function, limit values ​​for PM2.5 can be set on the particle counter.

During a measurement it is possible to record the measured values ​​with the temperature data logger. A memory with a storage capacity of approx. 12 measurement runs, each with 999 measurement points, is available for the particle counter. The interval can be set at different times on the particle counter.

The 8 Wh battery can be charged via the micro USB interface. The battery used in the temperature data logger enables an operating time of approx. 9 hours. Thus, the particle counter can carry out measurements over an entire working day before it has to be recharged. Since the battery is not permanently installed in the particle counter, it can be easily replaced.


Highlights

- Data storage for data logging
- Adjustable alarm when limit value is exceeded
- Transport case for safe transport
- Suitable for indicative measurements
- Measuring range 0 ... 1000 µm/m³
- Interface: Micro USB only for charging

Specification

Mass concentration 
Measurable particle sizesPM2.5 / PM10
Measuring range PM 2.50 ... 1000 µg/m³
Resolution1 µm
Accuracy PM 2.50 ... 100 µg/m³: ±10 µg/m³
 101 ... 1000 µg/m³: ±10% of measured value
  
Particle counter 
Measurable particle sizes0.3 / 2.5 µm
Resolution1 µm
Accuracyreference measurement
Number of maximum particles2,000,000 particles/L
  
Temperature 
Measuring range-10 ... 60 °C, 14 ... 140 °F
Resolution0.01 °C, °F
Accuracy±2 °C, ±3.6 °F
  
Humidity (RH) 
Measuring range0 ... 100 %
Resolution0.01 %
Accuracy±3 %
  
Further specifications 
Response time1 second
Warm up10 seconds
Mounting connection1/4" tripod connection
Dimensions intakeoutside: Ø13 mm / 0.51"
 inside: Ø7 mm / 0.27"
 height: 35 mm / 1.37"
  
Display3.2" LC color display
Power supply (mains adapter)  
primary: 100 ... 240 V AC, 50 / 60 Hz, 0.3 A
 secondary: 5 V DC, 2 A
Power supply (battery)3.7 V, 8.14 Wh, 18650
Battery lifeca. 9 hours
Interface
Micro USB for charging only
Auto power offturned off
 15, 30, 45 minutes
 1, 2, 4, 8 hours
Data memoryflash memory for approx. 12 measurement runs
 a measurement run contains 999 measurement points
Storage interval10, 30 seconds
 1, 5, 10, 30, 60 minutes
Dimensions222 x 80 x 46 mm / 8.7 x 3.1 x 1.8"
Weight320 g / 11.2 oz