HVAC Meter PCE-TG 150 F2.5
Need Technical Support?
Our engineers are available to help you select the right module for your application.
Description
Description
HVAC meter with data memory / Adjustable speed of sound /
Calibration reference mounted on the housing / Material thickness measurement up to 300 mm /
Limit alarm / Optional ISO calibration certificate
Calibration reference mounted on the housing / Material thickness measurement up to 300 mm /
Limit alarm / Optional ISO calibration certificate
The HVAC meter can measure material thicknesses up to 300 mm / 11.81". So that the material thickness of a wide variety of homogeneous materials can be measured, it is possible to store the corresponding speed of sound in the HVAC meter. For materials such as steel, aluminum, zinc, silver and gold, the appropriate sound speeds are already stored in the device library. This means that the HVAC meter can be used universally.
With the limit value function in the HVAC meter, individual maximum and minimum values can be stored. If the measured value of the test piece is outside the limits, the HVAC meter signals this visually. If necessary, the signaling can also be done acoustically by the HVAC meter in addition to the visual display. This is why the HVAC meter is used, for example, in quality assurance and in incoming goods inspections.
The HVAC meter has a data memory on which the measured values can be recorded. After a measurement sequence, the stored measurement values can be analyzed directly on the HVAC meter. The stored data are graphically displayed by the HVAC meter. In addition, each individual measuring point can be approached and read in the graphics of the HVAC meter. For a simplified analysis of the measured values, the average, the largest and smallest measured value is displayed on the HVAC meter. The HVAC meter can optionally be equipped with an ISO calibration certificate.
With the limit value function in the HVAC meter, individual maximum and minimum values can be stored. If the measured value of the test piece is outside the limits, the HVAC meter signals this visually. If necessary, the signaling can also be done acoustically by the HVAC meter in addition to the visual display. This is why the HVAC meter is used, for example, in quality assurance and in incoming goods inspections.
The HVAC meter has a data memory on which the measured values can be recorded. After a measurement sequence, the stored measurement values can be analyzed directly on the HVAC meter. The stored data are graphically displayed by the HVAC meter. In addition, each individual measuring point can be approached and read in the graphics of the HVAC meter. For a simplified analysis of the measured values, the average, the largest and smallest measured value is displayed on the HVAC meter. The HVAC meter can optionally be equipped with an ISO calibration certificate.
Highlights
- Measured value memory
- Calibration reference on the housing
- Automatic shutdown
- Material thickness measurement up to 300 mm / 11.81"
- Battery status indicator
- Optionally with ISO calibration certificate
- Calibration reference on the housing
- Automatic shutdown
- Material thickness measurement up to 300 mm / 11.81"
- Battery status indicator
- Optionally with ISO calibration certificate
Specification
| Measuring range | 1.20 ... 300.0 mm / 0.04 ... 11.81" |
| Resolution | 0.01 mm at ≤99.99 mm |
| 0.1 mm at ≥100.0 mm | |
| Accuracy | ±0.5 % of measured value + 0.05 mm |
| Storage space | 1500 measured values |
| Sensor | PCE-TG 2.5M |
| Probe frequency | 2.5 MHz |
| Temperature range | -10 ... 60 °C / 14 ... 140 °F |
| Diameter | Ø12mm |
| Further specifications | |
| Adjustable speed of sound | 1000 ... 9999 m/s |
| Smallest pipe diameter | Ø20 x 3 mm (steel) |
| Material library | 15 memory locations |
| Calibration reference | 4 mm |
| Display | 2.4 inch TFT LCD color display |
| with brightness adjustment | |
| Power supply | 3 x 1.5 V AA batteries |
| Automatic switch-off | switched off, 2, 5, 10, 30 minutes |
| Ambient conditions | 0 ... 40 °C / 32 ... 104 °F, <90 % RH, non-condensing |
| Dimensions | 163 x 82 x 38 mm / 6.4 x 3.2 x 1.5" |
| Weight | 320 g / 11.2 oz |