HVAC Meter PCE-TG 150 F2.5-ICA incl. ISO Calibration Certificate

Product Code:
PCE-TG 150 F2.5-ICA
Availability:
In Stock
Delivery Time
2–3 Business Days

Need Technical Support?

Our engineers are available to help you select the right module for your application.

Description

Description

HVAC meter with data memory / Adjustable speed of sound /
Calibration reference mounted on the housing / Material thickness measurement up to 300 mm /
Limit alarm / Optional ISO calibration certificate

The HVAC meter can measure material thicknesses up to 300 mm / 11.81". So that the material thickness of a wide variety of homogeneous materials can be measured, it is possible to store the corresponding speed of sound in the HVAC meter. For materials such as steel, aluminum, zinc, silver and gold, the appropriate sound speeds are already stored in the device library. This means that the HVAC meter can be used universally.

With the limit value function in the HVAC meter, individual maximum and minimum values ​​can be stored. If the measured value of the test piece is outside the limits, the HVAC meter signals this visually. If necessary, the signaling can also be done acoustically by the HVAC meter in addition to the visual display. This is why the HVAC meter is used, for example, in quality assurance and in incoming goods inspections.

The HVAC meter has a data memory on which the measured values ​​can be recorded. After a measurement sequence, the stored measurement values ​​can be analyzed directly on the HVAC meter. The stored data are graphically displayed by the HVAC meter. In addition, each individual measuring point can be approached and read in the graphics of the HVAC meter. For a simplified analysis of the measured values, the average, the largest and smallest measured value is displayed on the HVAC meter.

Highlights

- Measured value memory
- Calibration reference on the housing
- Automatic shutdown
- Material thickness measurement up to 300 mm / 11.81"
- Battery status indicator

Specification

Measuring range1.20 ... 300.0 mm  / 0.04 ... 11.81"
Resolution0.01 mm at ≤99.99 mm
 0.1 mm at ≥100.0 mm
Accuracy±0.5 % of measured value + 0.05 mm
  
Storage space1500 measured values
SensorPCE-TG 2.5M
Probe frequency2.5 MHz
Temperature range-10 ... 60 °C / 14 ... 140 °F
DiameterØ12mm
  
Further specifications 
Adjustable speed of sound  
1000 ... 9999 m/s
Smallest pipe diameterØ20 x 3 mm (steel)
Material library15 memory locations
Calibration reference4 mm
Display2.4 inch TFT LCD color display
 with brightness adjustment
Power supply3 x 1.5 V AA batteries
Automatic switch-offswitched off, 2, 5, 10, 30 minutes
Ambient conditions0 ... 40 °C / 32 ... 104 °F, <90 % RH, non-condensing
Dimensions163 x 82 x 38 mm / 6.4 x 3.2 x 1.5"
Weight320 g / 11.2 oz

Chat on WhatsApp