HVAC Meter PCE-PA 8000-ICA incl. ISO Calibration Certificate

Product Code:
PCE-PA 8000-ICA
Availability:
In Stock
Delivery Time
2–3 Business Days

Need Technical Support?

Our engineers are available to help you select the right module for your application.

Description

Description

HVAC Meter PCE-PA 8000
Real-time current, voltage and power consumption measurement / Built-in data recorder with adjustable rate / Includes current clamps, alligator clips, test leads, SD card memory and 2-year warranty against manufacturer defects

The HVAC meter is a portable handheld Clamp Meter used for the testing and inspection of 3-phase / 4-wire, 3-phase / 3-wire, 1-phase / 2-wire and 1-phase / 3-wire electrical circuits. This handy HVAC meter not only measures multiple electrical properties in real time, but also saves the measurement data in .xls format to the included SD card memory for quick and easy data transfer and analysis using Microsoft Excel.

The HVAC meter provides true RMS measurements of current and voltage. The HVAC meter also determines power factor (PF), phase angle (Φ), active power, apparent power and reactive power. The three current clamps included with the HVAC meter can be used on wires and cables with a diameter of 2.0" / 50 mm, allowing for use with the power grid. Also included in the delivery contents are four alligator clips, four test leads and an SD card. For real-time current, voltage and power consumption measurements at a glance, the HVAC meter features an easy-to-read 3.7" / 94 mm (320 x 240 pixel) LCD screen with backlight.


Highlights

- True RMS measurement for ACA, ACV
- True power: W, KW, MW
- VA, KVA, MVA, VAR, KVAR, MVAR
- PF (power factor), phase angle (Φ)
- KWH, KVAH, KVARH, PFH
- Voltage measurement range: 10 ... 600 ACV
- Current measurement range: 0.2 ... 1200 ACA
- Real-time current, voltage and power consumption measurement
- Built-in data recorder with adjustable rate: 2 ... 7,200 sec.
- Saves date- and time-stamped measurement data sets
- Complies with IEC 1010 and CAT III 600 V safety standards
- Includes current clamps, alligator clips, test leads, SD card memory and 2-year warranty against manufacturer defects
- incl. ISO Calibration Certificate
- USB data cable with software and spare AC power adapter sold separately - see accessories for details

Specification

Voltage (ACV)
Measurement rangeResolutionAccuracy
10 V ... 600 V (phase to neutral)0.1 V±(0.5 % + 0.5 V)
10 V ... 600 V (phase to neutral)
Current (ACA)
Measurement rangeResolutionAccuracy
20 A0.001 A (< 10 A)
0.01 A (≥ 10 A)
±(0.5 % + 0.1 V)
200 A0.01 A (< 100 A)
0.1 A (≥ 100 A)
±(0.5 % + 0.5 A)
1200 A0.1 A (< 1000 A)
1 A (≥ 1000 A)
±(0.5 A + 5 A)
Active power
Measurement rangeResolutionAccuracy
0 KW ... 9.999 KW0.001 KW±(1 % + 0.008 KW)
10 KW ... 99.99 KW0.01 KW±(1 % + 0.008 KW)
100 KW ... 999.9 KW0.1 KW±(1 % + 0.8 KW)
1 MW ... 9.999 MW0.001 MW±(1 % + 0.008 MW)
Apparent power
Measurement rangeResolutionAccuracy
0 KVA ... 9.999 KVA0.001 KVA±(1 % + 0.008 KVA)
10 KVA ... 99.99 KVA0.01 KVA±(1 % + 0.08 KVA)
100 KVA ... 999.9 KVA0.1 KVA±(1 % + 0.8 KVA)
1 MVA ... 9.999 MVA0.001 MVA±(1 % + 0.008 MVA)
Reactive power
Measurement rangeResolutionAccuracy
0 KVAR ... 9.999 KVAR0.001 KVAR±(1 % + 0.008 KVAR)
10 KVAR ... 99.99 KVAR0.01 KVAR±(1 % + 0.08 KVAR)
100 KVAR ... 999.9 KVAR0.1 KVAR±(1 % + 0.8 KVAR)
1 MVAR ... 9.999 MVAR0.001 MVAR±(1 % + 0.008 MVAR)
Active energy
Measurement rangeResolutionAccuracy
0 KWh ... 9.999 KWh0.001 KWh±(1 % + 0.008 KWh)
10 KWh ... 99.99 KWh0.01 KWh±(1 % + 0.08 KWh)
100 KWh ... 999.9 KWh0.1 KWh±(1 % + 0.8 KWh)
1 MWh... 9.999 MWh0.001 MWh±(1 % + 0.008 MWh)
Apparent energy
Measurement rangeResolutionAccuracy
0 KVAh ... 9.999 KVAh0.001 KVAh±(2 % + 0.008 KVAh)
10 KVAh ... 99.99 KVAh0.01 KVAh±(2 % + 0.08 KVAh)
100 KVAh ... 999.9 KVAh0.1 KVAh±(2 % + 0.8 KVAh)
1 MVAh... 9.999 MVAh0.001 MVAh±(2 % + 0.008 MVAh)
Reactive energy
Measurement rangeResolutionAccuracy
0 KVARh ... 9.999 KVARh0.001 KVARh±(2 % + 0.008 KVARh)
10 KVARh ... 99.99 KVARh0.01 KVARh±(2 % + 0.08 KVARh)
100 KVARh ... 999.9 KVARh0.1 KVARh±(2 % + 0.8 KVARh)
1 MVARh... 9.999 MVARh0.001 MVARh±(2 % + 0.008 MVARh)
Power factor
Measurement rangeResolutionAccuracy
0 ... 10.01±0.04
Phase angle
Measurement rangeResolutionAccuracy
-180º ... 180º0.1º±1º
Frequency
Measurement rangeResolutionAccuracy
45 Hz ... 65 Hz0.1 Hz0.1 Hz
General specifications
Display3.7" / 94.0 mm LCD (320 x 240 pixel) with backlight
Electrical propertiesACV, ACA, active power, apparent power, power factor, phase angle, mains frequency
Voltage range10 ... 600 ACV, automatic range selection
Safety standardsComplies with IEC 1010, CAT III 600 V
ACV input resistance10 MΩ
Operation frequency of current clamps40 Hz ... 1 kHz
Tested operation frequency of current clamps45 Hz ... 65 Hz
Overload protectionACV / 720 V RMS
ACA1300 A with current clamps
MemorySD card, up to 16 GB
Real-time display refresh rate1 second
Data loggerYes, fully integrated
Data logger sample rateAdjustable, 2 ... 7,200 seconds
Data outputUSB or RS-232, depending on the connection cable
Operating temperature0º C ... 50º C / 32° F ... 122° F
Operating humidity< 80 % RH
Power supply8 x 1.5 V AA batteries / AC power adapter
Input currentMeter: 300 mA DC
Clamp: 34 mA DC
Max. diameter2" / 50 mm
WeightMeter: 948 g / 2.09 lbs (with batteries)
Clamp: 467 g / 1.03 lbs (with cable)
DimensionsMeter: 225 x 125 x 64 mm / 8.8 x 4.9 x 2.5"
Clamp: 210 x 64 x 33 mm / 8.2 x 2.5 x 1.2"
Jaw: 86 mm / 3.3" (exterior)
Chat on WhatsApp