Current clamp up to 2000 A / TRMS measurement / Power measurement / Harmonic analysis / Graphic display with lighting / Data storage / Mains and battery operation

The PCE-GPA 50 current clamp is used to measure the current of 1- or 3-phase loads. This clamp is especially characterized by its measuring range up to 2000 A. Another highlight is the graphic display of the current clamp. Here, in addition to the numerical measured values, the waveform of the phase can also be displayed by the current clamp. Likewise, the current clamp can be used to measure voltages. As a result, the current clamp is able to calculate effective, apparent and reactive power with the help of the phase angle. In addition, the current clamp can measure other network parameters such as the energy, power factor and harmonic.

In addition to the extensive measuring functions, this current clamp distinguishes your data logger function. All measured values ​​can be stored by the current probe directly on a micro SD card. The clamp is powered by 2 1.5V AA batteries. However, it is also possible to operate the current clamp with a power supply for long-term measurements.

Highlights

- Graphic display
- Data logger on Micro-SD card
- Measurement for 1 and 3 phases
- Temperature measurement with thermocouple
- Voltage measurement 10V ... 600V AC RMS
- Current measurement 5 ... 2000 A AC RMS
- Current clamp opening 50 mm
- Harmonic distortion up to the 50th order
incl. ISO Calibration Certificate

Specification

Type of measurement 

AC voltage AC V    

Measuring range      ResolutionAccuracy
 10 ... 600V0.1V± (0.5% ... 3 digits)
 Peak to peak0.1V± (5% ... 30 digits)
    

AC AC A

5 ... 2000 A< 100 A: 0.01 A    < 200 A: ± (1% + 0.5 A)
  < 1000 A: 0.1 A> 200 A: ± (1% + 5 A)
 Peak to peak> 1000 A: 1 A± (5% + 30 digits)
    
Power factor (PF)0 ... 10.001± 0.04
    
Phase angle-180° ... 180°0.1°± 1° x PF
    
Frequency45 ... 65 Hz0.1 Hz± 0.2 Hz
    
Active, blind &0 ... 9,999 m0.1 ... 0.001 M± (1.5% + 20 digits)
apparent power(W / VA / VAR)(W / VA / VAR) 
    
Harmonic AC V1 ... 20th order0.1V± (2% + 5 digits)
 21 ... 50 order
0.1V± (4% + 5 digits)
    
Harmonic AC A

1 ... 20th order< 100 A: 0.01 A± (2% + 5 digits)
Alternating current < 1000 A: 0.1 A 
 21 ... 50 order> 1000 A: 1 A± (4% + 5 digits)
    
Harmonic AC V%1 ... 20th order0.1%± (2% + 10 digits)
 21 ... 50 order0.1%± (4% + 20 digits)
    
Absolute harmonic0 ... 20%0.1%± (2% + 5 digits)
distortion20.1 ... 100%0.1%± (6% + 10 digits)
    
Temperature type K-100 ... 199.9°C / -148 ... 391.8°F 0.1°C / 0.18°F    ± (1% + 1°C / 1.8°F)
thermocouple200 ... 1300°C / 392 ... 2372°F 1°C / 1.8°F± (1% + 2°C / 3.6°F)
    
DisplayGraphic LCD
AC V input impedance        10 MOhm
Frequency range40 Hz ... 1 kHz
Current Probe 
Calibrated frequency45 ... 65 Hz
Current Probe 
Overload protectionAC V: 720V RMS
 AC A: 2100 A
Data storageMicro SD card
Refresh rate1 second
Display 
Storage rate2 ... 7200s
Data storage 
Storage formatXLS
InterfaceSerial interface for live presentation to PC
 (SOFT-LUT-USB is required)
Power supply2 x 1.5V AA battery
 9V / 800-mA power supply
Current consumption60-mA DC
Clamp opening
50 mm
Operating conditions0 ... 50°C / 32 ... 122°F, max. 80% rh
WeightAbout 595 g / 1.3 lbs
Dimensions280 x 106 x 47 mm / 11 x 4.2 x 1.9 in